B7 · Reduction potentials and the hydrogen reference · Answer key
Download the printable PDF
Use the hydrogen reference and the reduction table to build a cell from any two half-cells, write its notation, predict observations and say what E° means.
Open the complete lesson
1. The hydrogen reference and the table
One reference for every half-cell
A voltmeter reads the push between two half-cells, so one half-cell alone can't have a measured value.
So chemists picked the standard hydrogen half-cell (2H⁺ + 2e⁻ → H₂, 1.0 mol/L, H₂ gas at 101.325 kPa) as the reference. They set it to exactly 0.00 V, like sea level for heights.
Join zinc to it and the meter reads 0.76 V, with electrons flowing from zinc to hydrogen. Electrons leave the anode, so zinc is the anode.
Use E°cell = E°cathode − E°anode. That gives 0.76 = 0.00 − E°(Zn²⁺/Zn), so E°(Zn²⁺/Zn) = −0.76 V. Negative means zinc ions are poorer than hydrogen ions at gaining electrons.
Now join copper. The meter reads 0.34 V, but electrons flow toward copper. Electrons go toward the cathode, so copper is the cathode.
So 0.34 = E°(Cu²⁺/Cu) − 0.00 and E°(Cu²⁺/Cu) = +0.34 V. Positive means copper ions are better than hydrogen ions at gaining electrons.
On the diploma: electron flow tells you which half is the anode, and that decides the sign. Name the anode before you write the equation.
Read the table
Every row is written as a reduction, with the electrons on the left.
A higher value means the particle on the left gains electrons better, so it is a stronger oxidizing agent. A lower value means the particle on the right gives electrons better, so it is a stronger reducing agent.
Ag⁺ (+0.80 V) is a stronger oxidizing agent than Cu²⁺ (+0.34 V). Zn is the strongest reducing agent of the three, because Zn²⁺/Zn is lowest at −0.76 V. You built this same ranking from experiments in B4.
If something is oxidized in a cell, we still use its printed reduction value and we never change its sign.
The subtraction in E°cell = E°cathode − E°anode already handles the sign. If you flip the sign first, you count it twice.
On the diploma: the strongest oxidizing agent has the highest value on the left. The strongest reducing agent has the lowest value on the right. Flipping the anode's sign is a common wrong option.
Hydrogen reference readings. Give the reduction value of each half-cell and the cell value from the cathode and anode values. Completed labels: Reference: 2H⁺ + 2e⁻ → H₂ is set at 0.00 V; Zn half-cell joined to the reference reads 0.76 V and Zn is the anode: E° = -0.76 V; Fe³⁺/Fe²⁺ +0.77 V cathode; I₂/I⁻ +0.54 V anode: E°cell = +0.23 V; E°cell = E°cathode − E°anode. Do you multiply E° by the electron count? No2. Cells from any two half-cells
Choose the cathode and the anode
Given Fe³⁺ + e⁻ → Fe²⁺ (+0.77 V) and I₂ + 2e⁻ → 2I⁻ (+0.54 V). It is the same rule as the Zn / Cu cell: the half with the higher value is reduced at the cathode.
So Fe³⁺ is reduced and I⁻ is oxidized. The iodine row runs backward at the anode.
Each I₂ made gives 2 electrons, and each Fe³⁺ takes only 1. So multiply the iron half by 2 to match the electrons.
Add the halves and cancel the electrons. The cell reaction is 2Fe³⁺ + 2I⁻ → 2Fe²⁺ + I₂. Check the charge: +6 − 2 = +4 on the left and +4 on the right.
E°cell = +0.77 − (+0.54) = +0.23 V. We did not double 0.77 V. A potential is a push per electron, not a total, so never multiply a table value by a coefficient.
On the diploma: write the two values side by side before anything else, and count electrons before you balance. Multiplying E° by a coefficient is a typical wrong option.
Watch: Which metal pulls electrons harder (Tyler DeWitt, “Introduction to Electrochemistry”, 6:06)
Inert electrodes and notation
In B6 both halves had a solid metal to connect the wire. The Fe³⁺/Fe²⁺ half-cell has only dissolved ions, so it needs an inert electrode, which means one that does not react.
Carbon is the usual choice, written C(s). It only gives electrons a surface to enter or leave. Iron metal would not work, because it could react itself.
Take MnO₄⁻/Mn²⁺ (+1.51 V) and Fe³⁺/Fe²⁺ (+0.77 V). The higher value is the cathode, so permanganate is reduced and the iron half is the anode.
C(s) | Fe²⁺(aq), Fe³⁺(aq) || MnO₄⁻(aq), H⁺(aq), Mn²⁺(aq) | C(s). The anode is on the far left, and a comma separates ions in one solution. H⁺ is there because the permanganate half needs it.
The reduction is MnO₄⁻ + 8H⁺ + 5e⁻ → Mn²⁺ + 4H₂O. Each Fe²⁺ gives 1 electron and each MnO₄⁻ takes 5, so multiply the iron half by 5.
E°cell = 1.51 − 0.77 = +0.74 V. This is the same reaction as the titration of iron(II) with permanganate.
On the diploma: put the anode on the left, the double line in the middle, and each dissolved ion in its own solution. A half-cell with no solid metal needs a carbon electrode.
3. Predict and interpret
Predict observations
We predict what we would see the same way as in B6. Read each half-reaction and ask what is used up and what is made.
At the cathode, purple MnO₄⁻ is reduced to almost colourless Mn²⁺, so the purple fades. The half-reaction has 8H⁺ on the left, so H⁺ is used up and the pH rises.
At the anode, lime green Fe²⁺ is oxidized to Fe³⁺, and the solution turns orange-yellow.
Carbon is inert, so it is in no half-reaction and its mass does not change. A mass change only happens if a solid is made or used up.
On the diploma: pH goes up when H⁺ is used up and down when H⁺ is made. Say which one the half-reaction does.
What the sign of E° means
Try 2Ag + Cu²⁺ → 2Ag⁺ + Cu. Cu²⁺ is reduced, so Cu²⁺/Cu (+0.34 V) is the cathode. Silver is oxidized, so Ag⁺/Ag (+0.80 V) is the anode.
E°cell = 0.34 − 0.80 = −0.46 V. The reaction is not spontaneous as written. The reverse, Cu + 2Ag⁺ → Cu²⁺ + 2Ag, has E° = +0.46 V, so it is spontaneous.
E° predicts the spontaneous direction under standard conditions, meaning 1.0 mol/L and 25 °C. It does not predict speed, because a spontaneous reaction can still be very slow.
E° also says nothing about other concentrations. The Nernst equation is not part of this course.
On the diploma: if E°cell is negative, say the reaction is not spontaneous as written and give the reverse reaction. A claim that positive E° means fast is a wrong option.
The completed diagram and text above answer the same labels as the student copy.
Answer the 12 core practice problems online · Completed notes and worked key
B7-P01
A silver half-cell is joined to the standard hydrogen half-cell and the voltmeter reads 0.80 V. Electrons flow toward the silver electrode. Find E° for Ag⁺ + e⁻ → Ag and name the anode.
- Electrons flow toward the cathode, so silver is the cathode and hydrogen is the anode.
- E°cell = E°cathode − E°anode, so 0.80 = E°(Ag⁺/Ag) − 0.00. Then E°(Ag⁺/Ag) = +0.80 V.
B7-P02
Explain why a table cannot list a measured voltage for a single half-cell, and what the standard hydrogen half-cell is used for.
- A voltmeter reads the difference between two half-cells, not the value of one alone.
- The standard hydrogen half-cell is set to 0.00 V. Every other value is the voltage measured against it.
B7-P03
Given Cl₂ + 2e⁻ → 2Cl⁻ (+1.36 V), Br₂ + 2e⁻ → 2Br⁻ (+1.07 V) and I₂ + 2e⁻ → 2I⁻ (+0.54 V). Name the strongest oxidizing agent and the strongest reducing agent among Cl₂, Br₂, I₂, Cl⁻, Br⁻ and I⁻.
- The strongest oxidizing agent is Cl₂, because it has the highest table value.
- The strongest reducing agent is I⁻, because I₂/I⁻ has the lowest value, so I⁻ gives up electrons most easily.
B7-P04
A student reverses the zinc row to Zn → Zn²⁺ + 2e⁻ and uses +0.76 V for the cell calculation. Which value should be used, and why?
- The printed table value, −0.76 V, should be used.
- All table values are table values. We never change the sign for an oxidation, because the subtraction E°cathode − E°anode already handles it.
B7-P05
Given Fe³⁺ + e⁻ → Fe²⁺ (+0.77 V) and I₂ + 2e⁻ → 2I⁻ (+0.54 V). Write the cell reaction and calculate E°cell.
- Fe³⁺/Fe²⁺ has the higher value, so Fe³⁺ is reduced at the cathode and I⁻ is oxidized at the anode.
- Multiply the iron half by 2 to match two electrons: 2Fe³⁺ + 2I⁻ → 2Fe²⁺ + I₂.
- E°cell = 0.77 − 0.54 = +0.23 V.
B7-P06
Given Cl₂ + 2e⁻ → 2Cl⁻ (+1.36 V) and I₂ + 2e⁻ → 2I⁻ (+0.54 V). Write the cell reaction in which chlorine oxidizes iodide and calculate E°cell.
- Each half moves two electrons, so no multiplier is needed.
- The cell reaction is Cl₂ + 2I⁻ → 2Cl⁻ + I₂.
- E°cell = 1.36 − 0.54 = +0.82 V.
B7-P07
In the cell 2Fe³⁺ + 2I⁻ → 2Fe²⁺ + I₂, a student multiplies 0.77 V by 2 because the iron half was doubled. Explain the error.
- A table value does not depend on how many copies of the half-reaction are written.
- The correct calculation is 0.77 − 0.54 = +0.23 V, with no multiplication.
B7-P08
Why does the Fe³⁺/Fe²⁺ half-cell need an inert electrode, and why is carbon a suitable choice?
- The half-cell has no solid metal. Something must carry electrons to and from the dissolved ions.
- Carbon is inert, so it does not react itself and only provides a surface. In cell notation it is written C(s).
B7-P09
Write the cell notation for the cell in which acidified MnO₄⁻ oxidizes Fe²⁺, using carbon electrodes. Name the anode and give E°cell (MnO₄⁻/Mn²⁺ +1.51 V; Fe³⁺/Fe²⁺ +0.77 V).
- The anode is the iron half, because Fe²⁺ is oxidized.
- C(s) | Fe²⁺(aq), Fe³⁺(aq) || MnO₄⁻(aq), H⁺(aq), Mn²⁺(aq) | C(s).
- E°cell = 1.51 − 0.77 = +0.74 V.
B7-P10
Given Br₂ + 2e⁻ → 2Br⁻ (+1.07 V) and Fe³⁺ + e⁻ → Fe²⁺ (+0.77 V). Will Br₂ oxidize Fe²⁺ under standard conditions? Write the equation and E°cell.
- Br₂ has the higher value, so it is reduced and Fe²⁺ is oxidized. Multiply the iron half by 2.
- The cell reaction is Br₂ + 2Fe²⁺ → 2Br⁻ + 2Fe³⁺. E°cell = 1.07 − 0.77 = +0.30 V, so it is spontaneous.
B7-P11
In the cell C(s) | Fe²⁺(aq), Fe³⁺(aq) || MnO₄⁻(aq), H⁺(aq), Mn²⁺(aq) | C(s), predict three things. Give the pH change near the cathode, the colour change at each electrode and the mass change of the electrodes.
- At the cathode MnO₄⁻ + 8H⁺ + 5e⁻ → Mn²⁺ + 4H₂O uses H⁺, so the pH rises, and the purple colour fades.
- At the anode, Fe²⁺ → Fe³⁺ + e⁻ makes the solution orange-yellow. The carbon electrodes are inert, so their mass does not change.
B7-P12
A student calculates E°cell = −0.46 V for 2Ag + Cu²⁺ → 2Ag⁺ + Cu and says the reaction is impossible and very fast in reverse. Explain what the sign does and does not tell us.
- A negative value says the reaction is not spontaneous as written under standard conditions. The reverse, Cu + 2Ag⁺ → Cu²⁺ + 2Ag, is spontaneous (+0.46 V).
- The sign says nothing about the speed. A spontaneous reaction can still be slow, and E° applies to 1.0 mol/L solutions only.