RT · Redox titrations · Notes and practice
Download the printable PDF
Use titre, mole ratio and volume to find an unknown concentration or mass, and judge how an error changes the result.
Open the complete lesson
Type in the blanks; your notes save on this device only. Use the backup controls at the bottom to keep a portable copy. Nothing is submitted.
1. The titration and its volumes
Two solutions, two jobs
A titration finds an unknown concentration. The is the solution of known concentration in the buret, the tall tube with a tap. The is the solution of unknown concentration in the flask.
We add titrant until the reaction is just complete. A delivers a fixed volume of analyte into the flask more precisely than a graduated cylinder. A delivers the titrant and measures how much was used.
The titre is the volume of titrant delivered: titre = . A buret counts up from zero as liquid leaves. Read the meniscus, the curved surface, at eye level.
With initial 0.40 mL and final 18.90 mL, the titre is . Never assume the start is 0.00.
On the diploma: the readings are given, and a wrong option often uses the final reading without subtracting.
Watch: A titration has one known and one unknown (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 0:24)
Choose the trials
One trial may hold a mistake, so we repeat it and average only the trials that agree within the limit the question gives. Given 18.50 mL, 18.60 mL and 19.60 mL with a 0.20 mL limit, the agreeing trials are .
Their average is . The 19.60 mL trial is left out because it , probably because too much titrant was added past the endpoint, which is the colour change that tells us to stop.
Watch: Average the volumes (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 8:31)
Watch: Leave out any trial more than 0.2 mL away (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 9:17)
Titration readings and chain. Find the titre, the average of the agreeing trials, and order the calculation chain.2. The equation and the endpoint
The equation gives the ratio
The balanced equation counts particles, so its coefficients also give mole ratios. Given MnO₄⁻ + 8H⁺ + 5Fe²⁺ → Mn²⁺ + 4H₂O + 5Fe³⁺. One MnO₄⁻ reacts with Fe²⁺, so n(Fe²⁺) = × n(MnO₄⁻).
The reason is electrons, as in B3. Each MnO₄⁻ takes (Mn +7 → +2) and each Fe²⁺ gives only (+2 → +3). So five Fe²⁺ give the electrons for one MnO₄⁻.
Reduction values from the data booklet: MnO₄⁻/Mn²⁺ +1.51 V and Fe³⁺/Fe²⁺ +0.77 V. The higher value is the oxidizing agent, so E° = 1.51 − 0.77 = . Acidified MnO₄⁻ or Cr₂O₇²⁻ is usually the strongest oxidizing agent in a titration.
A positive value means the direction is spontaneous. It does not say the reaction is fast.
On the diploma: the mole ratio comes from the equation in the question, and wrong options often use a 1 : 1 ratio.
Watch: Start with a balanced redox equation (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 0:57)
Watch: Match the electrons, then write the equation (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 5:01)
Watch: Required over given: the coefficient ratio (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 13:42)
Endpoint and equivalence
MnO₄⁻ is and Mn²⁺ in dilute solution is almost . While Fe²⁺ remains, each drop of purple turns colourless.
After the last Fe²⁺ reacts, one extra drop leaves a faint that stays. Permanganate is its own indicator, so no extra indicator is needed.
Equivalence is the exact point where moles are in the , and we calculate it. The endpoint is the colour change we . A deep pink means too much titrant was added, so the titre is too .
On the diploma: describe the endpoint as the first faint colour that stays, and keep equivalence (calculated) apart from endpoint (seen).
Watch: A redox titration: titrant and sample (Alberta Chemistry Teacher, “Chemistry 30 - Example: predicting redox reaction and observations of reactants and products”, 10:26)
Watch: Colours of ions on page 11 of the booklet (Alberta Chemistry Teacher, “Chemistry 30 - Example: predicting redox reaction and observations of reactants and products”, 10:47)
Watch: Orange fades to blue-green at the equivalence point (Alberta Chemistry Teacher, “Chemistry 30 - Example: predicting redox reaction and observations of reactants and products”, 11:45)
Watch: No indicator needed: use the colours of the reactants (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 17:01)
Watch: Permanganate: the purple tells you when to stop (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 18:21)
3. The calculation chain and errors
Titrant moles to concentration
Concentration is moles per litre, so volumes go in litres. Given 25.00 mL of Fe²⁺ and an average titre of 18.50 mL of 0.0200 mol/L MnO₄⁻. n(MnO₄⁻) = 0.0200 × 0.01850 = .
Use the ratio, 5 Fe²⁺ for each MnO₄⁻: n(Fe²⁺) = 5 × 3.70 × 10⁻⁴ = . Divide by the 0.02500 L to get .
We do not divide by the . It is the volume of titrant, not the volume of the solution that held the iron(II).
On the diploma: forgetting to convert mL to L is a common wrong option, so convert first and write the unit beside each number.
Watch: The same three steps every time (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 10:45)
Watch: Step 1: moles of the known (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 12:02)
Watch: Step 3: concentration of the unknown (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 14:55)
Aliquots and errors
An aliquot is a measured part of a larger solution. If 20.00 mL is taken from 100.0 mL, the whole is 100.0 ÷ 20.00 = 5.000 times bigger, so multiply the aliquot moles by .
Mass of iron = moles × . Mass percent = mass of iron ÷ mass of × 100.
The titre sets the moles of titrant, those set the moles of analyte, and those set the concentration. Adding too much titrant makes the titre too large, so all three come out too .
On the diploma: to judge an error, follow the chain and mark each step larger, smaller or unchanged before you choose.
Watch: Buret and pipette: what is in each (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 8:11)
Watch: Pipette precision and significant figures (Alberta Chemistry Teacher, “Chemistry 30 - Redox titration example. Acidified chromium (II) ions with dichromate.”, 15:45)
Use the diagram response box for labels and arrows in words, or draw on the printable PDF.
Answer the 12 core practice problems online · Completed notes and worked key
RT-P01
Buret readings: initial 3.05 mL, final 24.55 mL. Find the titre.
Response: ____________________
RT-P02
Trials: 20.10 mL, 20.20 mL, 21.30 mL. The limit is 0.20 mL. Which trials are averaged, and what is the average?
Response: ____________________
RT-P03
Given MnO₄⁻ + 8H⁺ + 5Fe²⁺ → Mn²⁺ + 4H₂O + 5Fe³⁺. How many moles of Fe²⁺ react with 2.0 × 10⁻⁴ mol of MnO₄⁻? Explain the ratio using electrons.
Response: ____________________
RT-P04
Use +1.51 V for MnO₄⁻/Mn²⁺ and +0.77 V for Fe³⁺/Fe²⁺. Which reactant is the oxidizing agent, and what is E°cell?
Response: ____________________
RT-P05
Given MnO₄⁻ + 8H⁺ + 5Fe²⁺ → Mn²⁺ + 4H₂O + 5Fe³⁺. A 25.00 mL sample of Fe²⁺(aq) needs 22.40 mL of 0.0150 mol/L MnO₄⁻(aq). Find c(Fe²⁺) in mol/L.
Response: ____________________
RT-P06
Explain why a permanganate titration of iron(II) needs no added indicator. Describe the colour before and at the endpoint.
Response: ____________________
RT-P07
Given 5H₂C₂O₄ + 2MnO₄⁻ + 6H⁺ → 10CO₂ + 2Mn²⁺ + 8H₂O. A 10.00 mL sample of H₂C₂O₄(aq) needs 12.60 mL of 0.0200 mol/L MnO₄⁻(aq). Find c(H₂C₂O₄) in mol/L.
Response: ____________________
RT-P08
A student divides the moles of Fe²⁺ by the titre instead of by the 25.00 mL flask volume. Explain the error and name the volume to divide by.
Response: ____________________
RT-P09
Given MnO₄⁻ + 8H⁺ + 5Fe²⁺ → Mn²⁺ + 4H₂O + 5Fe³⁺. A 10.00 mL aliquot from a 250.0 mL flask of Fe²⁺(aq) needs 15.60 mL of 0.0100 mol/L MnO₄⁻(aq). Find the mass of iron in the whole flask (Fe: 55.85 g/mol, Alberta Chemistry 30 Data Booklet).
Response: ____________________
RT-P10
A student rinses the buret with distilled water, not with the permanganate solution, before filling it. Is the calculated c(Fe²⁺) too high, too low or unchanged? Explain with the chain of calculation.
Response: ____________________
RT-P11
An iron tablet of mass 0.800 g is dissolved and made up to 100.0 mL. A 20.00 mL aliquot needs 14.10 mL of 0.0200 mol/L MnO₄⁻(aq). Find the mass percent of iron in the tablet (MnO₄⁻ + 8H⁺ + 5Fe²⁺ → Mn²⁺ + 4H₂O + 5Fe³⁺; Fe: 55.85 g/mol).
Response: ____________________
RT-P12
A bubble sits in the buret tip at the start and leaves during a titration. The recorded titre is larger than the liquid delivered to the flask. Is the calculated analyte concentration too high, too low or unchanged? Explain.
Response: ____________________