Lessons

Virtual force and field investigation

Simulated consequences of Coulomb’s law and an ideal uniform plate field. Point charges in vacuum; air is approximated as vacuum. This tests predictions within a mathematical model, not the model against nature. Coordinates are in metres; source charges are in μC.

Your investigation

Force: Predict F at r, 2r and 3r while keeping charges fixed. Record at least five separations. Plot F against r, then F against 1/r²; label numerical scales and units, and explain the transformed slope. Repeat with one charge doubled.

Field: Keep source separation fixed; set Q₂=0 to map a single source. Predict and record six probe locations. Repeat with a negative source, then an equal opposite pair. Record coordinates, components, magnitude and direction. Use actual source-to-probe distances for inverse-square comparisons.

Plate comparison: Select Uniform plate field. Keep Ey fixed and record six central positions. Compare the constant vector with a point-source map. Reverse Ey to reverse plate signs and field. The ideal model excludes fringing.

Accessible reference data / complete offline alternative

Calculated model data, not measurements. These tables support every collection task without using the controls. Direction angles are counterclockwise from +x. Plotting and explanation are still your work. CSV output from the controls has separate numerical force, field, coordinate and source-distance columns.

Force: five separations and a doubled-charge comparison

r (m)F (N), Q₁=+1 μC, Q₂=−1 μCF (N), Q₁=+2 μC, Q₂=−1 μC
0.2000.224750.4495
0.3000.0998888890.19977778
0.4000.05618750.112375
0.5000.035960.07192
0.6000.0249722220.049944444

Both forces on the right source point left. Hold charges and medium fixed within each five-row set.

Single positive: six probe locations

Q₁=+1 μC at (−0.200,0) m; Q₂=+0 μC at (+0.200,0) m. Source separation stays 0.400 m. A zero source has no contribution.

x (m)y (m)Ex (N/C)Ey (N/C)|E| (N/C)Angle (°)
0.0000.00022475002247500.00
0.2000.00056187.5056187.50.00
0.4000.00024972.22024972.220.00
-0.4000.000-2247500224750180.00
-0.2000.200022475022475090.00
-0.200-0.2000-224750224750270.00

Single negative: six probe locations

Q₁=-1 μC at (−0.200,0) m; Q₂=+0 μC at (+0.200,0) m. Source separation stays 0.400 m. A zero source has no contribution.

x (m)y (m)Ex (N/C)Ey (N/C)|E| (N/C)Angle (°)
0.0000.000-2247500224750180.00
0.2000.000-56187.5056187.5180.00
0.4000.000-24972.22024972.22180.00
-0.4000.00022475002247500.00
-0.2000.2000-224750224750270.00
-0.200-0.200022475022475090.00

Equal opposite pair: six probe locations

Q₁=+1 μC at (−0.200,0) m; Q₂=-1 μC at (+0.200,0) m. Source separation stays 0.400 m. A zero source has no contribution.

x (m)y (m)Ex (N/C)Ey (N/C)|E| (N/C)Angle (°)
0.0000.00044950004495000.00
0.2000.20040204.5-204647.7208559.6281.11
0.4000.000-199777.80199777.8180.00
-0.4000.000-199777.80199777.8180.00
-0.2000.20040204.5204647.7208559.678.89
-0.200-0.20040204.5-204647.7208559.6281.11

Uniform plate comparison: six locations

At each of (−0.600,−0.300), (0,−0.300), (+0.600,−0.300), (−0.600,+0.300), (0,+0.300), (+0.600,+0.300) m, with Ey fixed at −1000 N/C: Ex=0, Ey=−1000 N/C, |E|=1000 N/C, angle=270° (down). Upper plate is positive, lower negative. Reversing the setting to +1000 N/C reverses the field upward without changing its magnitude.

No student identifiers are collected. Readings stay in this page until you leave or download them.