B5 · The combined gas law · Completed notes

Goals: Sort the values in a gas question into "before" and "after". Rearrange the combined gas law for any one value. Use the combined gas law, with kelvin temperatures and matching units.

These are the completed notes. The blanks are filled in and each question is worked.

Slide 1 of 6 · When pressure and temperature both change

Boyle's law in lesson B3 and Charles's law in lesson B4 each changed one thing. Today two things change at once.

on the groundhigh in the air100 kPa27 °C40.0 kPa−33 °C

Key ideas

In real life, pressure and temperature often change together.

Lower pressure lets the balloon grow.

Lower temperature makes the balloon shrink.

Example

A weather balloon rises. The air pressure around it drops. What does that do to its volume?

  1. Lower pressure lets the balloon grow.
  2. So its volume gets bigger.

Try it

A weather balloon rises. The air around it gets colder. What does that do to its volume?

  1. Lower temperature makes the balloon shrink.
  2. So its volume gets smaller.

Slide 2 of 6 · Joining Boyle's law and Charles's law

The last slide needed one law for two changes. Both laws you know contain volume, so they can be joined.

P₁V₁ = P₂V₂Boyle's lawV₁/T₁ = V₂/T₂Charles's lawP₁V₁/T₁ = P₂V₂/T₂

Key ideas

Boyle's law and Charles's law both have volume in them.

The joined formula is called the combined gas law.

Only the amount of gas must not change.

Example

Which part of the combined gas law comes from Boyle's law?

  1. Boyle's law is P₁V₁ = P₂V₂.
  2. So the top of each side, pressure times volume, comes from it.

Try it

The temperature of a gas does not change. Which law does the combined gas law turn into?

  1. T₁ and T₂ are equal, so they cancel.
  2. P₁V₁ = P₂V₂ is left. That is Boyle's law.

Slide 3 of 6 · Sorting the values into before and after

The last slide gave the combined gas law. Before you can use it, you must sort the values in the question.

before (1)after (2)pressureP₁ = 100 kPaP₂ = 40.0 kPavolumeV₁ = 25.0 LV₂ = ?temperatureT₁ = 27 °CT₂ = −33 °CChange both temperatures to kelvin before you calculate.

Key ideas

A question gives five values and asks for one.

Sort the values into a before column and an after column.

Mark the value that is not given with a question mark.

Example

A gas at 95.0 kPa, 2.00 L and 20 °C changes to 3.00 L and 50 °C. Name the "before" values, the "after" values and the unknown.

  1. Before: P₁ = 95.0 kPa, V₁ = 2.00 L, T₁ = 20 °C.
  2. After: V₂ = 3.00 L, T₂ = 50 °C.
  3. The unknown is P₂.

Try it

A gas at 110 kPa, 5.00 L and 30 °C changes to 90.0 kPa and 10 °C. Name the "before" values, the "after" values and the unknown.

  1. Before: P₁ = 110 kPa, V₁ = 5.00 L, T₁ = 30 °C.
  2. After: P₂ = 90.0 kPa, T₂ = 10 °C.
  3. The unknown is V₂.

Slide 4 of 6 · Rearranging for the unknown

On the last slide you sorted the values and found the unknown. Now you rearrange the formula to get the unknown alone.

P₁V₁/T₁ = P₂V₂/T₂V₂ =P₁V₁T₂T₁P₂T₂ moved to the top. P₂ moved to the bottom.

Key ideas

To get V₂ alone, multiply both sides by T₂.

Then divide both sides by P₂.

Temperatures must be in kelvin.

The two pressures must be in the same unit.

Example

Use the combined gas law, P₁V₁/T₁ = P₂V₂/T₂. Rearrange it to get P₂ alone.

  1. Multiply both sides by T₂.
  2. Then divide both sides by V₂.
  3. P₂ = P₁V₁T₂ / (T₁V₂).

Try it

Use the combined gas law, P₁V₁/T₁ = P₂V₂/T₂. Rearrange it to get V₂ alone.

  1. Multiply both sides by T₂.
  2. Then divide both sides by P₂.
  3. V₂ = P₁V₁T₂ / (T₁P₂).

Slide 5 of 6 · Using the combined gas law

The last slide got the formula ready. Now you put the numbers in.

T₁ = 27 + 273 = 300 K, T₂ = −33 + 273 = 240 KV₂ = P₁V₁T₂ / (T₁P₂)V₂ = (100 kPa × 25.0 L × 240 K) / (300 K × 40.0 kPa)V₂ = 50.0 L

Key ideas

Change the temperatures to kelvin first.

Then put the numbers into the formula.

In the weather balloon question, the drop in pressure won.

Example

Use the combined gas law, P₁V₁/T₁ = P₂V₂/T₂, and T (K) = t (°C) + 273. The amount of gas does not change. A gas fills 8.00 L at 120 kPa and 27 °C. It changes to 90.0 kPa and 87 °C. What is the new volume?

  1. T₁ = 300 K and T₂ = 360 K.
  2. V₂ = P₁V₁T₂ / (T₁P₂).
  3. V₂ = (120 kPa × 8.00 L × 360 K) / (300 K × 90.0 kPa) = 12.8 L.

Try it

Use the combined gas law, P₁V₁/T₁ = P₂V₂/T₂, and T (K) = t (°C) + 273. The amount of gas does not change. A gas fills 3.00 L at 100 kPa and 127 °C. It changes to 150 kPa and 27 °C. What is the new volume?

  1. T₁ = 400 K and T₂ = 300 K.
  2. V₂ = P₁V₁T₂ / (T₁P₂).
  3. V₂ = (100 kPa × 3.00 L × 300 K) / (400 K × 150 kPa) = 1.50 L.

Slide 6 of 6 · Method: how to answer a gas law question

You just answered two combined gas law questions. Each time you did the same five things.

1List the values as "before" and "after".2Change temperatures to kelvin.3Match the units on both sides.4Rearrange for the unknown.5Calculate and round.list1kelvin2units3rearrange4answer5Check: the answer moves the way you expect.Used again in: lesson B8 and Unit D

Key ideas

Step 1: list the values as "before" and "after".

Step 2: change temperatures to kelvin.

Step 3: match the units on both sides.

Step 4: rearrange for the unknown. Step 5: calculate and round.

Example

Use the combined gas law, P₁V₁/T₁ = P₂V₂/T₂, and T (K) = t (°C) + 273. The amount of gas does not change. Use the five steps. A gas fills 6.00 L at 80.0 kPa and 7 °C. It changes to 100 kPa and 77 °C. What is the new volume?

  1. Step 1: P₁ = 80.0 kPa, V₁ = 6.00 L, P₂ = 100 kPa.
  2. Step 2: T₁ = 280 K and T₂ = 350 K. Step 3: both pressures are in kPa.
  3. Step 4: V₂ = P₁V₁T₂ / (T₁P₂).
  4. Step 5: put the numbers in and round.
  5. V₂ = (80.0 kPa × 6.00 L × 350 K) / (280 K × 100 kPa) = 6.00 L.

Try it

Use the combined gas law, P₁V₁/T₁ = P₂V₂/T₂, and T (K) = t (°C) + 273. The amount of gas does not change. Use the five steps. A gas fills 10.0 L at 200 kPa and 47 °C. It changes to 100 kPa and 15 °C. What is the new volume?

  1. Step 1: P₁ = 200 kPa, V₁ = 10.0 L, P₂ = 100 kPa.
  2. Step 2: T₁ = 320 K and T₂ = 288 K. Step 3: both pressures are in kPa.
  3. Step 4: V₂ = P₁V₁T₂ / (T₁P₂).
  4. Step 5: put the numbers in and round.
  5. V₂ = (200 kPa × 10.0 L × 288 K) / (320 K × 100 kPa) = 18.0 L.